Non-Woven Finish MgO Board

MgO Board for Fire-Rated Ductwork

Board components for HVAC and smoke-exhaust duct systems that require a defined, project-specific assembly.

Sulfycor non-woven magnesium oxysulfate boards can be evaluated for duct enclosure or board-duct systems. Board thickness, joints, supports, access panels, seals and the required complete-system rating must be reviewed together.

MOQ: 1 × 20GP container

MgO Fireproof Ductworks

System Boundary

Board Classification Is Not a Complete Duct Rating

Reaction-to-fire and surface-burning results support board-material review. A fire-resistance duration or smoke-control rating must be established for the complete tested or engineered duct assembly.

Typical Project Positions

✓ HVAC duct enclosure components

✓ Smoke-exhaust duct systems

✓ Service-shaft or duct-board applications

✓ Prefabricated duct sections subject to system review

Required Before Quotation

Duct function and assembly drawing

Board thickness, layers and joints

Supports, access doors, seals and penetrations

Required test method, duration, quantity and destination

Relevant Board Products

Non-Woven MgO Boards for Ductwork Review

The non-woven board series provides four current product specifications that can be reviewed against the proposed duct assembly.

Quality Evidence

Tested Board Performance You Can Review

EN 13501-1 and ASTM E84 results describe tested board samples. They do not on their own establish the fire-resistance duration, smoke-control performance or approval of a complete duct system.

EN 13501-1Class A1 Result

Reaction-to-fire classification for the tested magnesium sulfate board sample.

ASTM E84FSI 0 · SDI 0

Measured flame-spread and smoke-developed results for the tested board sample.

AS 1530.1Non-Combustibility

Independent test documentation for the submitted chloride-free MgO board sample.

EN 12467Physical Performance

Relevant strength, durability, fixing and impact properties were evaluated.

Certificates & Test Evidence

Ask for the reports that correspond to the product type, thickness, intended assembly and destination market. Results apply to the tested sample or assembly.

Procurement FAQ

Questions to Confirm Before Quotation

Clear project information helps us match the board, available documentation and commercial quotation.

Is an A1 board automatically a fire-rated duct?

No. A1 is a reaction-to-fire classification for the tested board. A duct rating applies to the complete assembly.

Can a fire-resistance duration be quoted from board data?

Only when supported by an applicable complete-system test or engineering assessment for the proposed construction.

Which details affect the duct specification?

Board layers and thickness, joints, supports, seals, access panels, penetrations, dimensions and installation method.

What documents are available?

Available board reports are matched to the selected specification; complete duct-system evidence is reviewed separately.

The Next Step

Start with the Duct Assembly and Required Rating

Send the system drawing, required test method or rating, board layers, dimensions, joints, supports, quantity and destination.

Send Four Project Details

Application · Size & Thickness · Quantity · Destination

Open the enquiry form and tell us what the board needs to do in your assembly.

MOQ: 1 × 20GP container